Frontier Pitts - logo
[contact-form-7 id="125" title="Product form"]

Benefits & Features

  • Successfully impact tested to PAS 68
  • Stopped 7.5t @ 50mph. The Ultimate Solution
  • Vehicle stopped within the aperture
  • Designed for ease of installation and maintenance
  • Hydraulically driven, three phase supply
  • Instantly reversible, 100% duty rated motor
  • Shallow foundation embedment depths of only
  • 400mm required. Foundation Type B/li>

Operating Speed

  • Typical speeds of 12-18 seconds* depending on configuration
  • EFO (extra fast operation) available depending on configuration

Options

  • UPS (Uninterrupted power supply), Accumulator or Manual Hand Pump allow a number of operations in power failure mode
  • In event of Power Failure options of Fail safe (remain in raised position) or Fail secure (remain in lowered position)
  • High Security Cabinet
  • Can be interfaced to any access control systems
  • Manual hand release for Power Fail Operation
  • Lower folding skirt

Safety

  • Vehicle detector loops
  • Safety photocell beams
  • Flashing Beacon
  • Audible Alarm

Civil Requirements

  • Barrier cabinet size (millimetres)
    L: 980 x W: 1400 x H: 1055
  • Barrier base (millimetres)
    L: 2800 x W: 2000 x D: 400
  • End rest base (millimetres)
    L: 2800 x W: 1500 x D: 400
  • Note: Power and control wiring ducts may be required

Electrical Requirements

  • 10 amp, 5 wire, 400V, 50Hz, Three phase and neutral supply

This is subject to a risk assessment to ensure the automatic equipment complies to BS EN 12453

Projects We Have Done